Homepage Watermakers Find a Dealer Prestigious Yachtbuilders About Sea Recovery Events / Boat Shows News / Press Releases

CORAL SEA - SPECIFICATIONS

Performance Rated Performance / Product Water Produced: +-15% at 820 PSI / 56.5 bar, 77°F / 25°C & 35,000 PPM TDS typical sea water

Production
Model # Per Hour Per Day

2800/3/V
3600/3/V

2800/3/H
3600/3/H

2800/3/M
3600/3/M

4200/4/V
5200/4/V

4200/4/H
5200/4/H
6200/4/H
6800/4/H

117 gal/442 lit
150 gal/568 lit

117 gal/442 lit
150 gal/568 lit

117 gal/442 lit
150 gal/568 lit

175 gal/662 lit
217 gal/820 lit

175 gal/662 lit
217 gal/820 lit
258 gal/978 lit
283 gal/1073 lit

2,800 gal / 10,599 lit
3,600 gal / 13,627 lit

2,800 gal / 10,599 lit
3,600 gal / 13,627 lit

2,800 gal / 10,599 lit
3,600 gal / 13,627 lit

4,200 gal / 15,899 lit
5,200 gal / 19,684 lit

4,200 gal / 15,899 lit
5,200 gal / 19,684 lit
6,200 gal / 23,469 lit
6,800 gal / 25,741 lit


Salt Rejection
(Chloride Ion)
Minimum 99.2%, Average 99.4%

Product Water Temperature Ambient to feed water temperature

Pressure Adjustment Automatically controlled

Salinity Monitoring Automatic electronic monitoring. Temperature compensated with the digital continuous readout. The salinity monitoring components of the system give a continuous TDS readout in ppm (parts per million), are temperature compensated, and of a fail safe design.

Salinity Range Designed for seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm)

Temperature Range Max. 122°F / 50°C, Min. 33°F / .5°C

System Feed Water Flow: 4.5 gpm / 17 lpm (depending on system)

Reverse Osmosis Membrane Selected High Rejection / High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element.

Chlorine Tolerance 0.1 PPM

pH Range 3-11 (typical seawater pH is 8)

System Pressure Feed Water: Maximum 35 psi / 2.41 bar / 2.46 Kg/cm2

System Operation Seawater nominal 820 psi / 56.5 bar / 57.66 Kg/cm2

Weight
Model Number
Weight

2800/3/V
3600/3/V

2800/3/H
3600/3/H

2800/3/M
3600/3/M

4200/4/V
5200/4/V

4200/4/H
5200/4/H
6200/4/H
6800/4/H

473 lbs / 215 Kg
485 lbs / 220 Kg

473 lbs / 215 Kg
485 lbs / 220 Kg

425 lbs / 193 Kg
435 lbs / 197 Kg

700 lbs / 318 Kg
750 lbs / 340 Kg

750 lbs / 340 Kg
800 lbs / 364 Kg
850 lbs / 386 Kg
900 lbs / 409 Kg

 

External Installation
Water Connections
Pipe sizes to be supplied by the installer for connection of the SRC supplied components. The below pipe threads are all US Standard.
 
Models 2800 & 3600
Feed Inlet: 3/4" ANSI Threaded Flange
Cleaning Inlet: 3/4" ANSI Threaded Flange
Brine Discharge: 3/4" ANSI Threaded Flange
Cleaning Return: 3/4" ANSI Threaded Flange
Product: 1/2" ANSI Threaded Flange
   
Models 4200, 5200, 6200 & 6800
Feed Inlet: 1" ANSI Threaded Flange
Cleaning Inlet: 1" ANSI Threaded Flange
Brine Discharge: 1" ANSI Threaded Flange
Cleaning Return: 1" ANSI Threaded Flange
Product: 1/2" ANSI Threaded Flange

Electrical Requirements (HP = Horse Power; FLA = Full Load Amperes; LRA = Locked Rotor Amperes - Start Up)
Model Phase Pump Motor Voltage VAC Hz NOA SUC
2800 & 3600         220 / 380 220 / 380
  Three Booster / HP 220 / 380 50 24 / 12 96 / 43
          208/230/460 208/230/460
  Three Booster / HP 208 / 230 / 460 60 18 / 16 / 9 54 / 48 / 27
          220 / 230 220 / 230
  Single Booster / HP 220 / 230 .125 32 / 26.5 128 / 108
             
          220 / 380 220 / 380
4200, 5200, 6200 & 6800 Three Booster / HP 220 / 380 50 36.6 / 21 146 / 84
          208/230/460 208/230/460
  Three Booster / HP 208 / 230 / 460 60 32.5 / 29.2 / 14.6 130 / 116.8 / 58.4
             

Amperage Rating of Circuit Breaker
Model AC Voltage Cycles Phase Circuit Breaker Amp
2800 & 3600 220 / 230 50 / 60 Single 50 / 40
2800 & 3600 220 / 380 50 Three 40 / 25
2800 & 3600 208 / 230 / 460 60 Three 40 / 25 / 20
4200 - 6800 220 / 380 50 Three 60 / 35
4200 - 6800 208 / 230 / 460 60 Three 60 / 40 / 30