| Production |
| Model # |
Per Hour |
Per Day |
450-1
700-1
900-1
900-2
1400-2
1800-2 |
19 gal / 71 lit
29 gal / 110 lit
38 gal / 142 lit
38 gal / 142 lit
58 gal / 221 lit
75 gal / 284 lit |
450 gal / 1,703 lit
700 gal / 2,650 lit
900 gal / 3,407 lit
900 gal / 3,407 lit
1400 gal / 5,300 lit
1800 gal / 6,814 lit |
|
|
|
Salt Rejection
(Chloride Ion) |
Minimum 99.2%, Average 99.4% |
|
|
| Product Water Temperature |
Ambient to feed water temperature |
|
|
| Pressure Adjustment |
User adjusted (manual) |
|
|
| Salinity Monitoring |
Automatic electronic monitoring. Temperature compensated with the digital continuous readout. The salinity monitoring components of the system give a continuous TDS readout in ppm (parts per million), are temperature compensated, and of a fail safe design. |
|
|
| Salinity Range |
Designed for seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm) |
|
|
| Temperature Range |
Max. 122°F / 50°C, Min. 33°F / .5°C |
|
|
| System Feed Water |
Flow: 4.5 gpm / 17 lpm (depending on system) |
|
|
| Reverse Osmosis Membrane |
Selected High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element. |
|
|
| Chlorine Tolerance |
0.1 PPM |
|
|
| pH Range |
3-11 (typical seawater pH is 8) |
|
|
| System Pressure |
Feed Water: Maximum 35 psi / 2.41 bar / 2.46 Kg/cm2 |
|
|
| System Operation |
Seawater nominal 820 psi / 56.5 bar / 57.66 Kg/cm2 |
|
|
| Weight |
|
|
Modular |
450-1
700-1
900-1
900-2
1400-2
1800-2 |
157 lbs / 69 Kg
160 lbs / 71 Kg
162 lbs / 72 Kg
169 lbs / 75 Kg
175 lbs / 76 Kg
180 lbs / 80 Kg |
153 lbs / 68 Kg
156 lbs / 69 Kg
158 lbs / 70 Kg
165 lbs / 73 Kg
171 lbs / 76 Kg
175 lbs / 78 Kg |
|
|
| |
|
External Installation
Water Connections |
Pipe sizes to be supplied by the installer for connection of the SRC supplied components. The below pipe threads are all US Standard. |
| |
|
|
| Feed Inlet: |
3/4" FNPT Female National Pipe Thread |
| Brine Discharge: |
3/4" FNPT Female National Pipe Thread |
| Product: |
3/8" MNPT Male National Pipe Thread |
|
|
| Electrical Requirements |
(NOA = Normal Operating Amps; SUC = Start Up Current) |
|
| Pump Type |
Phase |
Pump Motor |
Voltage VAC |
Hz |
NOA |
SUC |
| |
|
|
|
|
(110 / 220) |
| Plunger |
Single |
HP / Booster |
110-115 / 220-230 |
50/60 |
30 / 15 |
90 / 45 |
| Radial Axial |
Single |
HP / Booster |
220-230 / 380-460 |
50/60 |
35 / 17.5 |
95 / 48 |
|
|
|
|
|
|
|
| |
|
|
|
|
220 / 380 - 44 |
| Plunger |
Single |
HP / Booster |
220-230 / 380-460 |
50/60 |
11 / 5.5 |
30/15 |
| Radial Axial |
Three |
HP / Booster |
220-230 / 380-460 |
50/60 |
11 / 5.5 |
30/15 |
|
|
| Circuit Breaker Size |
| |
Operating AC Voltage |
Phase |
Recommended circuit breaker |
| Plunger Pump |
110-115 / 220-230 |
Single |
40 Ampere / 20 Ampere |
| Radial Axial Pump |
110-115 / 220-230 |
Single |
40 Ampere / 20 Ampere |
| Plunger Pump |
220 / 380 / 460 |
Three |
15 Ampere / 10 Ampere / 10 Ampere |
| Radial Axial Pump |
220 / 380 / 460 |
Three |
15 Ampere / 10 Ampere / 10 Ampere |
|
| |