Production |
Model # |
Per Hour |
Per Day |
AW 450-1
AW 700-1
AW 900-1
AW 900-2
AW 1400-2
AW 1800-2 |
19 gal / 71 lit
29 gal / 110 lit
38 gal / 142 lit
38 gal / 142 lit
58 gal /221 lit
75 gal / 284 lit |
450 gal / 1,703 lit
700 gal / 2,650 lit
900 gal / 3,407 lit
900 gal / 3,407 lit
1400 gal / 5,300 lit
1800 gal / 6,814 lit |
|
|
|
Salt Rejection
(Chloride Ion) |
Minimum 99.2%, Average 99.4% |
|
|
Product Water Temperature |
Ambient to feed water temperature |
|
|
Pressure Adjustment |
User adjusted |
|
|
Salinity Monitoring |
Automatic electronic monitoring. Temperature compensated with the solid state continuous "Bar LED" readout. The salinity monitoring components of the system give a continuous TDS readout in micromhos per cubic centimeter, are temperature compensated and of a fail safe design. |
|
|
Salinity Range |
Designed for seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm) |
|
|
Temperature Range |
Max. 122°F / 50°C, Min. 33°F / .5°C |
|
|
System Feed Water |
Flow: 3.0 - 4.2 gpm / 11.4 - 15.9 lpm (depending on system) |
|
|
Reverse Osmosis Membrane |
Selected High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element. |
|
|
Chlorine Tolerance |
0.1 PPM |
|
|
pH Range |
3-11 (typical seawater pH is 8) |
|
|
System Pressure |
Feed Water: Maximum 35 psi / 2.41 bar / 2.46 Kg/cm2 |
|
|
System Operation |
Seawater nominal 820 psi / 56.5 bar / 57.66 Kg/cm2. Brackish Varies w/PPM |
|
|
Weight |
|
|
Compact |
AW 450-1
AW 700-1
AW 900-1
AW 900-2
AW 1400-2
AW 1800-2 |
147 lbs / 67 Kg
150 lbs / 68 Kg
152 lbs / 69 Kg
159 lbs / 72 Kg
165 lbs / 75 Kg
170 lbs / 77 Kg |
147 lbs / 67 Kg
150 lbs / 68 Kg
152 lbs / 69 Kg
159 lbs / 72 Kg
165 lbs / 75 Kg
170 lbs / 77 Kg |
|
|
|
|
External Installation
Water Connections |
Pipe sizes to be supplied by the installer for connection of the SRC supplied components. The below pipe threads are all US Standard. |
|
|
|
Feed Inlet: |
3/4" FNPT Female National Pipe Thread |
Brine Discharge: |
1/2" FNPT Female National Pipe Thread |
Product: |
3/8" MNPT Male National Pipe Thread |
|
|
Electrical Requirements |
(HP = Horse Power; FLA = Full Load Amperes; LRA = Locked Rotor Amperes - Start Up) |
|
|
High Pressure Pump Electric Motor |
Phase |
Hz |
VAC |
HP |
FLA |
LRA |
Single |
50 |
110 |
3.0 |
23 |
136 |
Single |
50 |
220 |
3.0 |
11 |
68 |
Three |
50 |
220 |
3.0 |
9 |
40 |
Three |
50 |
380 |
3.0 |
5 |
20 |
Single |
60 |
115 |
3.0 |
25 |
136 |
Single |
60 |
230 |
3.0 |
12 |
68 |
Three |
60 |
230 |
3.0 |
8 |
35 |
Three |
60 |
460 |
3.0 |
4 |
18 |
|
|
|
Booster Pump & Feed Water Electric Motors |
Phase |
Hz |
VAC |
HP |
FLA |
LRA |
Single |
50/60 |
115 |
.5 |
7.4 |
34 |
Single |
50/60 |
220/230 |
.5 |
3.7 |
17 |
Three |
50/60 |
220/230 |
.5 |
2 |
12 |
Three |
50/60 |
380/460 |
.5 |
1 |
6 |
|
|
|
Recommended Circuit Breaker |
The final system configuration may have a large or different size Booster Pump therefore size your Circuit Breaker accordingly. The below chart is an approximation assuming standard pumps. |
|
|
|
Operating Voltage Hz & Phase |
Rec. Circuit Breaker Size |
115 VAC, 50/60 Hz, 1 Phase
230 VAC, 50/60 Hz, 1 Phase
208/230 VAC, 50/60 Hz, 3 Phase
380 VAC, 50/60 Hz, 3 Phase
460 VAC, 5060 Hz, 3 Phase |
35 Amperes
15 Amperes
10 Amperes
7.5 Amperes
7.5 Amperes |
|
|