AQUA MATIC DP - SPECIFICATIONS

Performance Rated Performance / Product Water Produced: +-15% at 820 PSI / 56.5 bar, 77°F / 25°C & 35,000 PPM TDS typical sea water

PRODUCTION
* Production may vary +/-20% | GPD: Gallons per day • LPD: Liters per day | * Based on 60 psi (4Bar) Dock Water Pressure.
Model # Fresh Water from sea water Ultra Pure Water from sea water Ultra Pure Water from dock water
A400C-1800GPD-1400GPD
A400C-2600GPD-2200GPD
A400C-3400GPD-2900GPD
1800 GPD | 6814 LPD
2600 GPD | 9842 LPD
3400 GPD | 12870 LPD
1400 GPD | 5300 LPD
2200 GPD | 8328 LPD
2900 GPD | 10978 LPD
1400 GPD | 5300 LPD
2200 GPD | 8328 LPD
2900 GPD | 10978 LPD

Salt Rejection
(Chloride Ion)
Minimum 99.2%, Average 99.4%

Product Water Temperature Ambient to feed water temperature

Pressure Adjustment Automatically controlled

Salinity Monitoring Automatic electronic monitoring. Temperature compensated with the digital continuous readout. The salinity monitoring components of the system give a continuous TDS readout in ppm (parts per million), are temperature compensated, and of a fail safe design.

Salinity Range Designed for seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm)

Temperature Range Max. 122°F / 50°C, Min. 33°F / .5°C

System Feed Water Flow: 4.5 gpm / 17 lpm (depending on system)

Reverse Osmosis Membrane Selected High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element.

Chlorine Tolerance 0.1 PPM

pH Range 3-11 (typical seawater pH is 8)

System Pressure Feed Water: Maximum 35 psi / 2.41 bar / 2.46 Kg/cm2

System Operation Seawater nominal 820 psi / 56.5 bar / 57.66 Kg/cm2

Weight
Model Number
Weight
A400C-1800GPD-1400GPD
A400C-2600GPD-2200GPD
A400C-3400GPD-2900GPD
413 lbs / 187 kg
413 lbs / 187 kg
428 lbs / 194 kg
 

External Installation
Water Connections
Pipe sizes to be supplied by the installer for connection of the SRC supplied components. The below pipe threads are all US Standard.
 
Feed Inlet: 3/4" FNPT Female National Pipe Thread
Brine Discharge: 3/4" FNPT Female National Pipe Thread
Product: 3/8" MNPT Male National Pipe Thread

Electrical Requirements (NOA = Normal Operating Amps; SUC = Start Up Current)
Pump Motor / HP Voltage VAC Hz Phase NOA SUC
Booster 1.5/2 220/380//230/460 50//60 3 4.8/2.4//5/2.5 14/7.2//15/7.5
Booster 1.5/1 115/230 50//60 1 14.2/7.1//18.2/9.1 54

Model Pump: Motor / HP Voltage VAC Hz Phase NOA SUC Circuit Breaker Amp
1800/1400 5 190/380//230/460 50/60 3 15.6/7.8//13.4/6.7 47/24//40/20 51/26/46/23
2600/2200-3400/2900 5//7.5 190/380//230/460 50/60 3 16.2/8.1/19/9.5 49/25//57/29 53/27//60/30
1800/1400 5 220/230 50/60 1 24/21.8 72/66 83/73