| Performance |
Rated Performance / Product Water Produced: +-15% at 820 PSI / 57 BAR, 77°F / 25°C & 35,000 PPM TDS typical sea water |
|
|
| Membrane Configuration / Production |
Model |
Number
of Vessels |
Membrane Configuration |
Production / Hour |
Production / Day |
25m3 |
1 |
Single |
270 gal / 1,022 lit |
6,500 gal / 24,605 lit |
45m3 |
2 |
Single |
511 gal / 1,934 lit |
12,000 gal / 45,424 lit |
45m3 |
1 |
Double |
511 gal / 1,934 lit |
|
60m3 |
3 |
Single |
666 gal / 2,521 lit |
16,000 gal / 60,566 lit |
72m3 |
4 |
Single |
791gal / 2,994 lit |
19,000 gal / 71,922 lit |
72m3 |
2 |
Double |
791gal / 2,994 lit |
19,000 gal / 71,922 lit |
90m3 |
6 |
Single |
958 gal / 3,626 lit |
23,000 gal / 87,065 lit |
90m3 |
3 |
Double |
958 gal / 3,626 lit |
23,000 gal / 87,065 lit |
|
|
|
Salt Rejection
(Chloride Ion) |
Minimum 99.2%, Average 99.4% |
|
|
| Product Water Temperature |
Ambient to feed water temperature |
|
|
| Pressure Adjustment |
Automatically controlled |
|
|
| Salinity Monitoring |
utomatic electronic monitoring. Temperature compensated with the solid state continuous "Bar LED" readout. The salinity monitoring components of the system give a continuous TDS readout in micromhos per cubic centimeter, are temperature compensated and of a fail safe design. |
|
|
| Salinity Range |
Designed for seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm) |
|
|
| Temperature Range |
Max. 102°F / 39°C, Min. 36°F / .2°C |
|
|
| System Feed Water |
Flow: 30 gpm / 114 lpm (depending on system) |
|
|
| Reverse Osmosis Membrane |
Selected High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element. |
|
|
| Chlorine Tolerance |
0.1 PPM |
|
|
| pH Range |
3-11 (typical seawater pH is 8) |
|
|
| System Pressure |
Feed Water: Maximum 35 psi / 2.41 bar / 2.46 Kg/cm2 |
|
|
| System Operation |
Seawater nominal 820 psi / 59 bar / 59.7 Kg/cm2. Brackish Varies w/PPM |
|
|
| Weight |
|
|
| 25m3 |
1900 lbs / 864 Kg |
| 45m3 |
2100 lbs / 954 Kg |
| 45m3 |
2100 lbs / 954 Kg |
| 60m3 |
2200 lbs / 1000 Kg |
| 72m3 |
2400 lbs / 1090 Kg |
| 72m3 |
2500 lbs / 1136 Kg |
| 90m3 |
2400 lbs / 1090 Kg
|
| 90m3 |
2400 lbs / 1090 Kg
|
|
|
|
External Installation
Water Connections |
Pipe sizes to be supplied by the installer for connection of the SRC supplied components. The below pipe threads are all US Standard. |
| |
|
|
| 3" MODELS |
|
| Feed Inlet: |
1-1/2" ANSI Threaded Flange |
| Brine Discharge: |
1-1/2" ANSI Threaded Flange |
| Product: |
1" ANSI Threaded Flange |
|
|
| Electrical Requirements |
| |
220 / 50Hz / 3PH |
380 / 50Hz / 3PH |
440 / 50Hz / 3PH |
208 / 60Hz / 3PH |
230 / 60Hz / 3PH |
460 / 60Hz / 3PH |
Data |
| (All Systems) |
|
|
|
|
|
|
|
|
| |
| THP = Total Horse Power; FLA = Full Load Amperes; RCB = Recommended Circuit Breaker |
| |
|