Homepage About Parker Sea Recovery Standard Line of Parker Sea Recovery Water Systems Information about Parker Sea Recovery Custom Water Systems Industries we serve Find a Dealer Parker Sea Recovery Customer List Parker Sea Recovery Events - Tradeshows

Maximum Production: From 5,500 to 21,000 gallons (20,820 to 79,493 liters) per day

Tasman Sea Features Tasman Sea Specifications Tasman Sea Dimensions Tasman Sea Modular Accessories Tasman Sea Modular Consumables

Tasman Sea Specifications

Performance Rated Performance / Product Water Produced: +-15% at 820 PSI / 57 BAR, 77°F / 25°C & 35,000 PPM TDS typical sea water

Production
Model # Per Hour Per Day
21m3/S1 229 gal / 867 lit 5,500 gal / 20,820 lit
38m3/S1 417 gal / 1,577 lit 10,000 gal / 37,854 lit
53m3/S1 583 gal / 2,208 lit 14,000 gal / 52,996 lit
     
64m3/D1 708 gal / 2,681 lit 17,000 gal / 64,352 lit
72m3/D1 792 gal / 2,997 lit 19,000 gal / 71,923 lit
79m3/D1 875 gal / 3,312 lit 21,000 gal / 79,493 lit
     
38m3/S2 417 gal / 1,577 lit 10,000 gal / 37,854 lit
64m3/S2 708 gal / 2,681 lit 17,000 gal / 64,352 lit

79m3/S2

875 gal / 3,312 lit

21,000 gal / 79,493 lit


Salt Rejection
(Chloride Ion)
Minimum 99.2%, Average 99.4%

Product Water Temperature Ambient to feed water temperature

Pressure Adjustment Automatically controlled

Salinity Monitoring utomatic electronic monitoring. Temperature compensated with the solid state continuous "Bar LED" readout. The salinity monitoring components of the system give a continuous TDS readout in micromhos per cubic centimeter, are temperature compensated and of a fail safe design.

Salinity Range Designed for seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm)

Temperature Range Max. 102°F / 39°C, Min. 36°F / .2°C

System Feed Water Flow: 30 gpm / 114 lpm (depending on system)

Reverse Osmosis Membrane Selected High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element.

Chlorine Tolerance 0.1 PPM

pH Range 3-11 (typical seawater pH is 8)

System Pressure Feed Water: Maximum 35 psi / 2.41 bar / 2.46 Kg/cm2

System Operation Seawater nominal 820 psi / 59 bar / 59.7 Kg/cm2. Brackish Varies w/PPM

Weight
Model Number
Weight
21m3/S1 1900 lbs / 864 Kg
38m3/S1 2000 lbs / 909 Kg
53m3/S1 2100 lbs / 954 Kg
   
64m3/D1 2300 lbs / 1045 Kg
72m3/D1 2400 lbs / 1090 Kg
79m3/D1 2500 lbs / 1136 Kg
   
38m3/S2 2000 lbs / 909 Kg
64m3/S2 2200 lbs / 1000 Kg
79m3/S2

2400 lbs / 1090 Kg


External Installation
Water Connections
Pipe sizes to be supplied by the installer for connection of the SRC supplied components. The below pipe threads are all US Standard.
 
3" MODELS  
Feed Inlet: 1-1/2" ANSI Threaded Flange
Brine Discharge: 1-1/2" ANSI Threaded Flange
Product: 1" ANSI Threaded Flange

Electrical Requirements (HP = Horse Power; FLA = Full Load Amperes; LRA = Locked Rotor Amperes - Start Up)
   
Booster Pump
Electric Motor
Hz VAC HP FLA LRA
50 220 1.5 6 38
50 380 1.5 3 19
50 415 1.5 3 18
60 208 1.5 6 38
60 230 1.5 5 34
60 460 1.5 2.5 17
   
High Pressure Pump Electric Motor
Hz VAC HP FLA LRA
50 220 30 & 2 62.4 390
50 380 30 & 2 31.2 198
50 415 30 & 2 29 180
60 208 30 & 2 63.4 390
60 230 30 & 2 57.8 370
60 460 30 & 2 28.9 185

Recommended Circuit Breaker The final system configuration may have a large or different size Booster Pump therefore size your Circuit Breaker accordingly. The below chart is an approximation assuming standard pumps.
 
Operating Voltage Hz & Phase Rec. Circuit Breaker Size

220 VAC, 50 Hz, Three Phase
380 VAC, 50 Hz, Three Phase
415 VAC, 50 Hz, Three Phase

208 VAC, 60 Hz, Three Phase
230 VAC, 60 Hz, Three Phase
460 VAC, 60 Hz, Three Phase

90 Amperes
50 Amperes
50 Amperes

90 Amperes
90 Amperes
50 Amperes