Coral Sea Series Tasman Sea The New North Sea Modular Series The North Sea Find a Dealer Events / Tradeshows About Danfoss Sea Recovery
North Sea Series Features North Sea Series Specifications North Sea Series Dimensions North Sea Series Accessories North Sea Series Consumables

North Sea Specifications

Performance Rated Performance / Product Water Produced: +-15% at 820 PSI / 57 BAR, 77°F / 25°C & 35,000 PPM TDS typical sea water

Production
Model # Per Hour Per Day
42m3/S2 458 gal / 1,735 lit 11,000 gal/41,639 lit
76m3/S2 833 gal / 3,155 lit 20,000 gal/75,708 lit
98m3/S2 1,083 gal / 4,101 lit 26,000 gal/98,420 lit
     
121m3/D2 1,333 gal / 5,047 lit 32,000 gal/121,133 lit
132m3/D2 1,458 gal / 5,520 lit 35,000 gal/132,489 lit
144m3/D2 1,583 gal / 5,994 lit 38,000 gal/143,845 lit
     
144m3/D3 1,583 gal / 5,994 lit 38,000 gal /143,854 lit
159m3/D3 1,750 gal / 6,624 lit 42,000 gal / 158,987 lit
167m3/D3 1,833 gal / 6,940 lit 44,000 gal / 166,558 lit

Salt Rejection
(Chloride Ion)
Minimum 99.2%, Average 99.4%

Product Water Temperature Ambient to feed water temperature

Pressure Adjustment Automatically controlled

Salinity Monitoring utomatic electronic monitoring. Temperature compensated with the solid state continuous "Bar LED" readout. The salinity monitoring components of the system give a continuous TDS readout in micromhos per cubic centimeter, are temperature compensated and of a fail safe design.

Salinity Range Designed for seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm)

Temperature Range Max. 102°F / 39°C, Min. 36°F / .2°C

System Feed Water Flow: 45-65 gpm / 170-246 lpm (depending on system)

Reverse Osmosis Membrane Selected High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element.

Chlorine Tolerance 0.1 PPM

pH Range 3-11 (typical seawater pH is 8)

System Pressure Feed Water: Maximum 35 psi / 2.41 bar / 2.46 Kg/cm2

System Operation Seawater nominal 820 psi / 59 bar / 59.7 Kg/cm2. Brackish Varies w/PPM

Weight
Model Number
Weight
42m3/S2

3700 lbs / 1678 Kg
76m3/S2 4000 lbs / 1814 Kg
98m3/S2 4300 lbs / 1950 Kg
121m3/D2 4800 lbs / 2177 Kg
132m3/D2 5100 lbs / 2313 Kg
144m3/D2 5400 lbs / 2449 Kg
144m3/D3 5400 lbs / 2449 Kg
159m3/D3 5850 lbs / 2653 Kg
167m3/D3 6300 lbs / 2857 Kg


External Installation
Water Connections
Pipe sizes to be supplied by the installer for connection of the SRC supplied components. The below pipe threads are all US Standard.
 
3" MODELS  
Feed Inlet: 1-1/2" ANSI Threaded Flange
Brine Discharge: 1-1/2" ANSI Threaded Flange
Product: 1" ANSI Threaded Flange

Electrical Requirements (HP = Horse Power; FLA = Full Load Amperes; LRA = Locked Rotor Amperes - Start Up)
   
Booster Pump
Electric Motor
Hz VAC HP FLA LRA
50 220 3 8 64
50 380 3 4 32
50 440 3 4 30
60 208 3 9 64
60 230 3 8 58
60 460 3 4 29

Hz VAC HP FLA LRA
50 220 5 13 108
50 380 5 7 54
50 440 5 7 52
60 208 5 14 110
60 230 5 13 100
60 460 5 7 50
   
High Pressure Pump Electric Motor
Hz VAC HP FLA LRA
50 220 50 120 792
50 380 50 70 458
50 440 50 60 396
60 200 50 120 648
60 208 50 120 877
60 230 50 120 618
60 460 50 60 309

Recommended Circuit Breaker The final system configuration may have a large or different size Booster Pump therefore size your Circuit Breaker accordingly. The below chart is an approximation assuming standard pumps.
 
Operating Voltage Hz & Phase Rec. Circuit Breaker Size
220 VAC, 50 Hz, Three Phase
380 VAC, 50 Hz, Three Phase
440 VAC, 50 Hz, Three Phase

200 VAC, 60 Hz, Three Phase
208 VAC, 60 Hz, Three Phase
230 VAC, 60 Hz, Three Phase
460 VAC, 60 Hz, Three Phase

50 Amperes
90 Amperes
75 Amperes

160 Amperes
160 Amperes
150 Amperes
75 Amperes