Coral Sea Series Tasman Sea The New North Sea Modular Series The North Sea Find a Dealer Events / Tradeshows About Danfoss Sea Recovery
Coral Sea Series Features Coral Sea Series Specifications Coral Sea Series Dimensions Coral Sea Series Accessories Coral Sea Series Consumables

Coral Sea Specifications

Performance Rated Performance / Product Water Produced: +-15% at 820 PSI / 57 BAR, 77°F / 25°C & 35,000 PPM TDS typical sea water

Production
Model # Per Hour Per Day

2800/3/V
3600/3/V

2800/3/H
3600/3/H

2800/3/M
3600/3/M

4200/4/V
5200/4/V

4200/4/H
5200/4/H
6200/4/H
6800/4/H

117 gal/442 lit
150 gal/568 lit

117 gal/442 lit
150 gal/568 lit

117 gal/442 lit
150 gal/568 lit

175 gal/662 lit
217 gal/820 lit

175 gal/662 lit
217 gal/820 lit
258 gal/978 lit
283 gal/1073 lit

2,800 gal / 10,599 lit
3,600 gal / 13,627 lit

2,800 gal / 10,599 lit
3,600 gal / 13,627 lit

2,800 gal / 10,599 lit
3,600 gal / 13,627 lit

4,200 gal / 15,899 lit
5,200 gal / 19,684 lit

4,200 gal / 15,899 lit
5,200 gal / 19,684 lit
6,200 gal / 23,469 lit
6,800 gal / 25,741 lit


Salt Rejection
(Chloride Ion)
Minimum 99.2%, Average 99.4%

Product Water Temperature Ambient to feed water temperature

Pressure Adjustment Automatically controlled

Salinity Monitoring utomatic electronic monitoring. Temperature compensated with the solid state continuous "Bar LED" readout. The salinity monitoring components of the system give a continuous TDS readout in micromhos per cubic centimeter, are temperature compensated and of a fail safe design.

Salinity Range Designed for seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm)

Temperature Range Max. 102°F / 39°C, Min. 36°F / .2°C

System Feed Water Flow: 8 - 16 gpm / 30 - 61 lpm (depending on system)

Reverse Osmosis Membrane Selected High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element.

Chlorine Tolerance 0.1 PPM

pH Range 3-11 (typical seawater pH is 8)

System Pressure Feed Water: Maximum 35 psi / 2.41 bar / 2.46 Kg/cm2

System Operation Seawater nominal 820 psi / 59 bar / 59.7 Kg/cm2. Brackish Varies w/PPM

Weight
Model Number
Weight

2800/3/V
3600/3/V

2800/3/H
3600/3/H

2800/3/M
3600/3/M

4200/4/V
5200/4/V

4200/4/H
5200/4/H
6200/4/H
6800/4/H

435 lbs / 197 Kg
473 lbs / 215 Kg

435 lbs / 197 Kg
473 lbs / 215 Kg

395 lbs / 180 Kg
425 lbs / 193 Kg

700 lbs / 318 Kg
750 lbs / 340 Kg

750 lbs / 340 Kg
800 lbs / 364 Kg
850 lbs / 386 Kg
900 lbs / 409 Kg


External Installation
Water Connections
Pipe sizes to be supplied by the installer for connection of the SRC supplied components. The below pipe threads are all US Standard.
 
3" MODELS  
Feed Inlet: 3/4" ANSI Threaded Flange
Cleaning Inlet: 3/4" ANSI Threaded Flange
Brine Discharge: 3/4" ANSI Threaded Flange
Cleaning Return: 3/4" ANSI Threaded Flange
Product: 1/2" ANSI Threaded Flange
   
4" MODELS  
Feed Inlet: 1" ANSI Threaded Flange
Cleaning Inlet: 1" ANSI Threaded Flange
Brine Discharge: 1" ANSI Threaded Flange
Cleaning Return: 1" ANSI Threaded Flange
Product: 3/4" ANSI Threaded Flange

Electrical Requirements (HP = Horse Power; FLA = Full Load Amperes; LRA = Locked Rotor Amperes - Start Up)
   
Booster Pump
Electric Motor
Phase Hz RPM VAC HP FLA LRA
Single 50 2875 220 1 6 40
Single 60 3450 230 1 6 39
Three 50 2875 220 1 3 26
Three 50 2875 380 1 2 15
Three 60 3450 208 1 4 28
Three 60 3450 230 1 3 25
Three 60 3450 460 1 2 13
   
High Pressure Pump Electric Motor
Phase Hz RPM VAC HP FLA LRA
Single 50 1428 220 5 26 183
Single 60 1725 230 5 21 146
Three 50 1428 220 5 21 138
Three 50 1428 380 5 10 80
Three 60 1725 208 5 15 122
Three 60 1725 230 5 13 110
Three 60 1725 460 5 7 55
   
 
Phase Hz RPM VAC HP FLA LRA
Three 50 1428 220 10 33 276
Three 50 1428 380 10 19 160
Three 60 1725 208 10 29 243
Three 60 1725 230 10 26 220
Three 60 1725 460 10 13 110

Recommended Circuit Breaker The final system configuration may have a large or different size Booster Pump therefore size your Circuit Breaker accordingly. The below chart is an approximation assuming standard pumps.
 
Operating Voltage Hz & Phase Rec. Circuit Breaker Size Circuit Breaker Size



220 VAC, 50 Hz, Three Phase
380 VAC, 50 Hz, Three Phase
208 VAC, 60 Hz, Three Phase
230 VAC, 60 Hz, Three Phase
460 VAC, 60 Hz, Three Phase

220 VAC, 50 Hz, Single Phase
230 VAC, 60 Hz, Single Phase

2800 - 3600 gpd

50 Amperes
25 Amperes
35 Amperes
35 Amperes
15 Amperes

65 Amperes
55 Amperes

4200 - 6800 gpd

70 Amperes
40 Amperes
65 Amperes
60 Amperes
30 Amperes

n/a
n/a