Homepage About Parker Sea Recovery Standard Line of Parker Sea Recovery Water Systems Information about Parker Sea Recovery Custom Water Systems Industries we serve Find a Dealer Parker Sea Recovery Customer List Parker Sea Recovery Events - Tradeshows

Maximum Production:
From 2,800 to 6,800 Gal (10,599 to 25,741 liters) per day

Coral Sea Series Features Coral Sea Series Specifications Coral Sea Series Dimensions Coral Sea Series Accessories Coral Sea Series Consumables

Coral Sea Specifications

Performance Rated Performance / Product Water Produced: +-15% at 820 PSI / 57 BAR, 77°F / 25°C & 35,000 PPM TDS typical sea water

Production
Model # Configuration No. of Vessels Vessel Size Per Hour Per Day

2800
3600
4200
5200
6200
6800

V | H | M
V | H | M
V | H | M
V | H | M
V | H | M
V | H | M

3
4
3
4
5
6

3"
3"
4"
4"
4"
4"

117 gal/442 lit
150 gal/568 lit
175 gal/662 lit
217 gal/820 lit
258 gal/978 lit
283 gal/1073 lit

2,800 gal / 10,599 lit
3,600 gal / 13,627 lit
4,200 gal / 15,899 lit
5,200 gal / 19,684 lit
6,200 gal / 23,469 lit
6,800 gal / 25,741 lit


Salt Rejection
(Chloride Ion)
Minimum 99.2%, Average 99.4%

Product Water Temperature Ambient to feed water temperature

Pressure Adjustment Automatically controlled

Salinity Monitoring utomatic electronic monitoring. Temperature compensated with the solid state continuous "Bar LED" readout. The salinity monitoring components of the system give a continuous TDS readout in micromhos per cubic centimeter, are temperature compensated and of a fail safe design.

Salinity Range Designed for seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm)

Temperature Range Max. 102°F / 39°C, Min. 36°F / .2°C

System Feed Water Flow: 8 - 16 gpm / 30 - 61 lpm (depending on system)

Reverse Osmosis Membrane Selected High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element.

Chlorine Tolerance 0.1 PPM

pH Range 3-11 (typical seawater pH is 8)

System Pressure Feed Water: Maximum 35 psi / 2.41 bar / 2.46 Kg/cm2

System Operation Seawater nominal 820 psi / 59 bar / 59.7 Kg/cm2. Brackish Varies w/PPM

 

External Installation
Water Connections
Pipe sizes to be supplied by the installer for connection of the SRC supplied components. The below pipe threads are all US Standard.
 
3" MODELS  
Feed Inlet: 3/4" ANSI Threaded Flange
Cleaning Inlet: 3/4" ANSI Threaded Flange
Brine Discharge: 3/4" ANSI Threaded Flange
Cleaning Return: 3/4" ANSI Threaded Flange
Product: 1/2" ANSI Threaded Flange
   
4" MODELS  
Feed Inlet: 1" ANSI Threaded Flange
Cleaning Inlet: 1" ANSI Threaded Flange
Brine Discharge: 1" ANSI Threaded Flange
Cleaning Return: 1" ANSI Threaded Flange
Product: 3/4" ANSI Threaded Flange

 
Electrical Requirements:
Models 2800 - 3600 Models 4200 - 6800
Specs
HP
FLA
LRA
220/50Hz/1PH 7 1/2 & 2 48 274
230/60Hz/1PH 7 1/2 & 2 39 219
220/50Hz/3PH 7 1/2 & 2 36 207
380/50Hz/3PH 7 1/2 & 2 17 120
208/60Hz/3PH 7 1/2 & 2 27 183
230/60Hz/3PH 7 1/2 & 2 24 165
460/60Hz/3PH 7 1/2 & 2 12 82
Specs
HP
FLA
LRA
220/50Hz/1PH NA NA NA
230/60Hz/1PH NA NA NA
220/50Hz/3PH 10 & 2 39 301
380/50Hz/3PH 10 & 2 21 174
208/60Hz/3PH 10 & 2 35 265
230/60Hz/3PH 10 & 2 31 240
460/60Hz/3PH 10 & 2 16 120