Homepage About Parker Sea Recovery Standard Line of Parker Sea Recovery Water Systems Information about Parker Sea Recovery Custom Water Systems Industries we serve Find a Dealer Parker Sea Recovery Customer List Parker Sea Recovery Events - Tradeshows

Maximum Production: Up to 1,200 metric tons per day.

Download Atlantic Sea Brochure

Atlantic Sea Features Atlantic Sea Specifications Atlantic Sea Accessories Atlantic Sea Consumables

Atlantic Sea Specifications

Performance Rated Performance / Product Water Produced: +-15% at 820 PSI / 57 BAR, 77°F / 25°C & 35,000 PPM TDS typical sea water

Membrane Configuration / Production
Model
Number
of Membranes
Energy Recovery Available / Type
Production / Hour
Production / Day
250m3
12
Yes / I-Save
2,752 gal / 10,417 lit
66,043 gal / 250,000 lit
300m3
16
Yes / I-Save
3,302 gal / 12,500 lit
79,252 gal / 300,000 lit
400m3
20
Yes / I-Save
4,403 gal / 16,667 lit
105,669 gal / 400,000 lit
500m3
30
Yes / I-Save
5,504 gal / 20,833 lit
132,086 gal / 500,000 lit
600m3
50
Yes / I-Save
6,604 gal / 25,000 lit
158,503 gal / 600,000 lit
750m3
60
Yes / I-Save
8,255 gal / 31,250 lit
198,129 gal / 750,000 lit
1,000m3
100
Yes / I-Save
11,007 gal / 41,667 lit
264,172 gal / 1,000,000 lit
1,200m3
120
Yes / I-Save
13,209 gal / 50,000 lit
317,006 gal / 1,200,000 lit

Salt Rejection
(Chloride Ion)
Minimum 99.2%, Average 99.4%

Product Water Temperature Ambient to feed water temperature

Pressure Adjustment Automatically controlled

Salinity Monitoring utomatic electronic monitoring. Temperature compensated with the solid state continuous "Bar LED" readout. The salinity monitoring components of the system give a continuous TDS readout in micromhos per cubic centimeter, are temperature compensated and of a fail safe design.

Salinity Range Designed for seawater use up to 50,000 PPM TDS (NaCl) (typical seawater salinity is 35,000 ppm)

Temperature Range Max. 102°F / 39°C, Min. 36°F / .2°C

System Feed Water Flow: 30 gpm / 114 lpm (depending on system)

Reverse Osmosis Membrane Selected High Rejection/High Yield aromatic tri-polyamid, thin film composite, spiral wound, single pass, high rejection reverse osmosis membrane element.

Chlorine Tolerance 0.1 PPM

pH Range 3-11 (typical seawater pH is 8)

System Pressure Feed Water: Maximum 35 psi / 2.41 bar / 2.46 Kg/cm2

System Operation Seawater nominal 820 psi / 59 bar / 59.7 Kg/cm2. Brackish Varies w/PPM

Estimated Energy Savings Per M3 of Water Produced
Model Number
Savings
250m3
40%
300m3
40%
400m3
44%
500m3
44%
600m3
44%
750m3
44%
1,000m3
48%
1,200m3
49%